Heat Sink PCB / Al-Base PCB
Features
- With high thermal conductivity, this PCB protects devices from thermal destruction
(Official thermal conductivity spec: 3.0W/m, K –) - High tracking resistance assures safety against electricity fire. (CTI: 600V+)
- It features high voltage endurance and assures safety for electric fire. (Through voltage: 3.0kV / 100μm)
- UL approved (2012.06)
Product Picture


Product Specification
Item | Specification | Note |
---|---|---|
Surface Cu thickness | 35, 70 [μm] | 35 [μm] is the standard. |
Insulation layer thickness | 80, 100, 120 [μm] | Use epoxy resin including heat dissipation filler. 100 [μm] is the standard. |
Base Al thickness | 0.6, 1.0, 1.5, 2.0 [mm] | Base Al thickness 1.0 [mm], Al-Mg type A5052 is standard |
Surface Treatment | OSP (Pbf-HAL, Electroless Ni-Au) | OSP is standard. (Please contact us for Pbf-HAL, Electroless Ni-Au) |
Surface Insulation Treatment | Liquid photoresist, thermosetting solder resist | Other than standard green, high gloss white, mat black is available. |
Other | Non-through hole | Circuit is only formed on the surface. Not available for front and back conduction. |
Product Properties
Item | Test Condition | Results |
---|---|---|
Solder Heat Resistance | pretreatment (40 [°C] / 90 [%] / 96 [Hr]) : Solder floating method (260+5-0 [°C] / 20 [sec] / 2 [times]) |
No floating of Cu, delamination or inflation |
Withstand Voltage | Applied voltage (DC 100 [V] / 1 [min]) : Between circuits (0.1 [mm]) |
No mechanical damage, no spark over |
Applied voltage (DC 5000 [V] / 1 [min]) : Between layers |
||
Insulation | Applied voltage (DC 100 [V] / 1 [min]) : Between circuits (0.1 [mm]) |
More than 10 [GΩ] |
Applied voltage (DC 500 [V] / 1 [min]) : Between layers |
||
Humidity Insulation | 40 [°C], 90 [% Rh], 240 [Hr], DC 100 [V], 1 [min] : Between circuits (0.1[mm]) and between layers |
More than 100 [MΩ] |
Migration Resistance | 85 [°C], 85 [% Rh], DC 50 [V], 1000 [Hr] : Between circuits (0.1[mm]) and between layers |
More than 100 [MΩ] |
Above numbers are actual measurements as a reference, not assurance of quality.